Modem Tutorial - Configuring Popular Communications Software
About Modem Tutorial
Copyright (c) 1991 Patrick Chen. All rights reserved.
Modem Tutorial Index
Configuring Popular Communications Software to Work with High-speed Modems
Below are brief instructions for configuring some popular communications programs to work with a high-speed modem. The particular initialization string is for the ATI 9600etc/e modem. It is assumed that the appropriate initialization string to use is AT&F2&C1&D2S7=60.
Make sure you save the changes you make.
Procomm Plus 2.0
To change the modem initialization string: (Global, i.e. it works with every dialing entry)
- Load Procomm, press Alt-S
- Select Modem Options
- Select Modem Commands
- Press A
- Change the initialization string to AT&F2&C1&D2S7=60^M
To set the software to wait 60 seconds for connection: (Global)
- Load Procomm, press Alt-S
- Select Modem Options
- Select General Options
- Press A
- Type 60 and press Return
To enable hardware flow control: (Global)
- Load Procomm, press Alt-S
- Select Terminal Options
- Press D (hardware flow control)
- Press Space Bar to toggle, press Return to accept
- Press C (software flow control)
- Press Space Bar to toggle, press Return to accept
Telix
To change the modem initialization string: (Global)
- Press Alt-O
- Select Modem and dialing
- Select A (Init String)
- Change the initialization string to ATZ^M~~~AT&F2&C1&D2S7=60^M
To set the software to wait 60 seconds for connection: (Global)
- Press Alt-O
- Select Modem and dialing
- Select K (Dial time) and enter 60 press Return
To enable hardware flow control (Global)
- Press Alt-O
- Select Terminal options
- Press J (XON/XOFF software flow control)
- Select Off
- Select K (CTS/RTS hardware flow control)
- Select On
- Press ESC to exit
Qmodem
To change the modem initialization string: (Global)
- Press Alt-N
- Press M to select Modem menu
- Select Modem Commands
- Press Return
- Change the initialization string to AT&F2&C1&D2S7=60^M
To set the software to wait 60 seconds for connection: (Global)
- Press Alt-N
- Press M to select Modem menu and Press Return to select Communication
- Parameters
- Press H to select Timeout delay
- Type 60 and press Return
- ESC to exit
To enable hardware flow control: (Global)
- Press Alt-N
- Select Toggles
- Press Return to toggle XON/XOFF flow
- Select CTS/RTS flow
- Press Return to toggle
- ESC
- ESC
- Press E for Exit
- Save Changes
HyperAccess 5
Note: HyperAccess 5 supports the ATI 9600etc/e. However, HyperAccess 5 does not let you edit the initialization string directly. You can add additional setup commands to change the modem settings for each individual dialing entry.
To change the modem initialization string: (Individual, i.e. it works only with the particular dialing entry)
- Select Define system settings from the Main menu
- Select Modify
- Use cursor to select the system to modify and press Enter
- Select Hardware from the System settings menu
- Select Modem
- Select Additional modem setup commands
- Type S7=60
- Press ESC twice to go back the Main menu
- To set the software to wait 60 seconds for connection:
- N/A
To enable hardware flow control: (Individual)
- Select Define system settings from the Main menu
- Select Modify
- Use cursor to select the system to modify and press Enter
- Select Hardware from the System settings menu
- Make sure that Data terminal ready signal is output on DTR, delete
- RTS if it is listed
- Select Communications port
- Select Incoming hardware handshaking and type CTS
- Select Outgoing hardware handshaking and type RTS
Crosstalk for Windows
To change the modem initialization string: (Global)
- Pull down Setup menu and select Modem...
- Select Custom and click on Settings
- Change the initialization string to ^M~AT&F2&C1&D2S7=60^M
- Click OK
To set the software to wait 60 seconds for connection: (Individual)
- Pull down File menu and select Open a phone book entry
- Open the phone book entry
- Pull down Setup menu and select Session
- Click on More
- Change the value in Allow xx seconds for the host to answer
To enable hardware flow control: (Individual)
- Pull down File menu and select Open a phone book entry
- Open the phone book entry
- Pull down Setup menu and select Device
- Click on RTS/CTS and click OK
MicroPhone II (for Macintosh)
To change the modem initialization string: (Individual)
- Choose Settings Menu
- Select Communications
- Choose V.32 Standard from the Modem Driver list box
- Click OK
- Hold down the Command key and choose Scripts menu
- Select Modify Script
- Click the Modem Scripts button
- Double-click on Modem_Init
- Double-click on the first line that says Set Variable * mcmd from Expression "'AT....'"
- Change the initialization string in the lower right box to 'AT&F2&C1&D2S7=60^M'
- Double-click on the second line that says Set Variable * mcmd from Expression "'AT....'"
- Change the initialization string in the lower right box to 'AT&F2&C1&D2S7=60^M'
- Click OK
- Press the Option key and choose the File menu
- Select Save Modem Driver (If you want to save the driver under a new name, select Save Modem Driver As... in the File Menu. Name the new driver, and save it into the Modem Folder.)
- To set the software to wait 60 seconds for connection:
- N/A
To enable hardware flow control: (Individual)
- Pull down Settings Menu
- Select Communications
- Click on the Hardware Handshake box
ZTerm (for Macintosh)
To change the modem initialization string: (Global)
- Choose Settings Menu and select Modem
- Change Init String to AT&F2&C1&D2S7=60^M
To set the software to wait 60 seconds for connection: (Individual)
- Choose Settings Menu and select Modem
- Edit Dial Timeout
To enable hardware flow control: (Global)
- Choose Settings Menu and Select Flow Control
- Uncheck Xon-Xoff Receive
- Uncheck Xon-Xoff Send
- Check HW Handshake
Next
Other Settings for Your Communications Software
Modem Tutorial Index